EK-ARENG OŰ

MAIN TECHNICAL DATA

Production parameters

Chemical reagents and components

Name

The standard,

kg/hour

Anti-foaming agent

0,001

Coal 207EA

0,175

Coal 207C

0,057

Alumagel

0,114

MEA

6,400

Energy resources and water

Name

Standard, kW/h

Electric power

900

Name

m3/hour

For the production of demineralized water

3,50

For feeding open cooling towers

4,20

For household needs

1,00

Technical data

Name and
general requirements for

equipment,
parameter

Type, size, quantity

1

2

Appearance, installation quality

in accordance with the installation diagram and the standard sample, no defects are allowed

Classification of environmental conditions - moderate according to GOST 15150-69, accommodation category 2

suitable for operation at ambient temperatures from minus 30°C to plus 40°C, relative humidity up to 98% at plus 25°C

Productivity (in agreement with the customer) kg/h, at least

2500

Flue gas inlet temperature, ºС

350

Inlet fire gas pressure (excess), mBar

0...30

CO2 output temperature, ºС

minus 24...minus 27

The pressure of the resulting gas, bar

15…18

Efficiency, %, not lower

75

Time to enter operating mode, min., no more than

30

Demineralized water consumption, m 3/h, no more than

2

Pressure in the pneumatic line, Bar, no more than

6

Recommended heated area (including water treatment and operator room), m²

432

(24x18 m)

Weight of the equipment installed in the room, kg

45000

Recommended area for the installation of outdoor equipment

144

(18x8 m)

Weight of outdoor equipment (excluding flue gases), kg

86000

Nominal supply voltage, V

380 (three-phase current)

Power supply frequency, Hz

50…60

Supply voltage in the control circuit, V

24 (direct current)

Power consumption (excluding auxiliary units), kW

620

Specific energy consumption, kW/t CO2

455

Refrigerant type

R404Freon

Name and general requirements for

equipment, parameter

Type, size,

quantity

Adjusted sound power level, dB A, no more than

110

The surfaces of the extraction station, made of non-corrosion-resistant materials, are painted.

Metallic and non-metallic (inorganic) anticorrosive coatings must comply with the requirements of EN ISO 12944

The tightness class of equipment operating under pressure and its fittings is set in accordance with EN 60529.

Large-sized units (including column equipment) are disassembled for easy transportation to the customer's site.

To issue a technical proposal in which all parameters are determined in relation to the customer's specifications, it is necessary to first determine the composition of the fire gas.

To start working on developing a technical proposal, you must at least fill out a questionnaire (attached).

After that, an accurate model of the extraction station is developed with the customer's specialists, a contract is concluded, and the project development begins.